Rinnai RHFE-263FAII User Manual
Page 5

5
Rinnai Corporation RHFE-263FA
Features
Clean Heating Forced Flue Type
Easy Operation One-Touch Ignition
Sensible Temperature Control Feature
Comfortable Room Temperature Control and
Display
Warm Air Outlet at Floor Level (keeps your feet
warm)
Function Lock
Room Temperature Setting Memory
Clean the Air Filter - Indicator Lamp
Energy Saving Economy Setting
Humidifier Tray
Air Flow Directional Louvers
Direct Vent Easily Installed
Proportional Heating Variable Capacity
Hush! Quiet Operation
Modern Design Minimizes Floor Space
Requirements
Failure Message Display
See the installation instructions for the parts list of
the vent kit.
The A Vent Kit is included with the appliance.
The following flue manifold sizes are available:
Name
Kit
No. fits
walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Flue Manifolds
Natural Gas
Propane Gas
Minimum supply gas pressure
3.5 in (89 mm) W.C.
8.0 in (203 mm) W.C.
Maximum supply gas pressure
10.5 in (267 mm) W.C.
13.0 in (330 mm) W.C.
Manifold test pressure-High
2.3 in (58 mm) W.C.
3.7 in (94 mm) W.C.
Manifold test pressure-Low
0.6 in (16 mm) W.C
1.1 in (27 mm) W.C.
BTU/hour input
Low 5500 - High 11000
BTU/hour output
Low 4450 - High 8800
Low 5700 - High 11000
Low 4600 - High 8800
Appliance Specifications