beautypg.com

Extension installation kit – Rinnai RHFE-263FAII User Manual

Page 22

background image

22

Rinnai Corporation RHFE-263FA

Extension

Installation

Kit

If necessary, extention kits are available to extend the exhaust line and air intake hose between the manifold
and the appliance. The maximum vent length is 13 feet (4m) with 2 bends. The bent pipe attached to the
appliance dose not count toward the max limit of 2 bends. The maximum vertical length is 8 feet (2.4m). Any
length (horizontal and vertical) in excess of 8 feet (2.4m) must be sloped 3

downward toward the flue manifold

to allow condensate to drain to the outside. Do not allow any low points in the exhaust line where condensate
will collect.

Vent extensions installed in unconditioned air space must be insulated with high temperature insulation and
must be accessible.

Vent extentions must not be concealed per NFPA 54 and must be accessible allowing inspection and repair.
Decorative covers are available from Rinnai.

Examples

Extension to the left (facing appliance)

Extension to the right (facing appliance)

Extension through the top

INCORRECT
Too many bends (limit is 2)
Air intake hose is above exhaust
pipe.

LONG BENT ELBOW

LONG BENT

ELBOW

PIPE STOPPER A

EXHAUST

PIPE

PIPE CLAMP

EXHAUST

ELBOW

AIR INTAKE HOSE

CLAMP

PIPE STOPPER A

EXHAUST PIPE

CLAMP

PIPE

STOPPER A

PIPE CLAMP

PIPE CLAMP

AIR INTAKE

HOSE

AIR INTAKE

HOSE

EXHAUST

PIPE

EXHAUST

ELBOW

CLAMP