beautypg.com

2 trace functions – Renesas SuperH HS0720KCU01HE User Manual

Page 33

background image

27

7. If the settings of the Event condition or the sequential conditions are changed during

execution of the program, execution will be suspended. (The number of clocks to be
suspended during execution of the program is a maximum of about 102 bus clocks
(B

φ). If the bus clock (Bφ) is 66.6 MHz, the program will be suspended for 1.53 μs.)

8. If the settings of Event conditions or the sequential conditions are changed during

execution of the program, the emulator temporarily disables all Event conditions to
change the settings. During this period, no Event condition will be satisfied.

9. If the break condition before executing an instruction is set to the instruction followed

by DIVU and DIVS, the factor for halting a break will be incorrect under the following
condition:
If a break occurs during execution of the above DIVU and DIVS instructions, the break
condition before executing an instruction, which has been set to the next instruction,
may be displayed as the factor for halting a break.

10. If the break conditions before and after executing instructions are set to the same

address, the factor for halting a break will be incorrectly displayed. The factor for
halting a break due to the break condition after executing an instruction will be
displayed even if a break is halted by the break condition before executing an
instruction.

11. Do not set the break condition after executing instructions and BREAKPOINT

(software break) to the same address.

12. When the emulator is being connected, the user break controller (UBC) function is not

available.

2.2.2 Trace

Functions

The emulator supports the trace functions listed in table 2.8.

Table 2.8 Trace Functions

Function

Internal Trace

AUD Trace

Branch trace

Supported

Supported

Memory access trace

Supported

Supported

Software

trace

Not

supported

Supported