beautypg.com

Ricoh Rioch 5 Mega Pixel CCD Monochrome PoCL Camera Link Camera FV-L500B1 User Manual

Page 29

background image



29/31

FV-L500B1
User’s Guide Rev. 1.02



Command No.

Command Descriptions

68H:

DIGITAL_

CLAMP[7

0]

[Digital clamp] Initial data: DIGITAL_CLAMP[7..0] = 0

Sets the digital clamp.

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

D7 to D5:

No function

Always set as “000”

D4:

Mirror image

0: Normal image

1: Mirror image

D3:

No function

Always set as “0”

D2:

Clamp mode

0: Auto adjust

1: Manual adjust

D1 to D0:

No function

Always set as “00”

The following two settings have to be set when the “manual adjust” is selected at the clamp mode:

Manual digital clamp (Left): MD-CLAMP_L[15..0] (6A & 6BH)

Manual digital clamp (Right): MD_CLAMP_R[15..0] (6C & 6DH)

6AH:

MD_CLAMP_L

[7

0]

6BH:

MD_CLAMP_L

[15

8]

[Manual digital clamp (Left)]

Initial data: MD_CLAMP_L[15..0] = The factory adjusted value, data range: 0 to 1023

Sets the manual digital clamp for the left side of the image when the manual adjust is selected at the digital

clamp (68H).

6CH:

MD_CLAMP_R

[7

0]

6CH:

MD_CLAMP_R

[15

8]

[Manual digital clamp (Right)]

Initial data: MD_CLAMP_R[15..0] = The factory adjusted value, data range: 0 to 1023

Sets the manual digital clamp for the right side of the image when the manual adjust is selected at the digital

clamp (68H).

78H:

TESTP[7

0]

[Test pattern selection] Initial data: TESTP[7..0] = 0

Sets the test pattern output from the camera.

D[7..0]

D7

D6

D5

D4

D3

D2

D1

D0

00H:

Video output

01H:

Gray scale

02H:

Ramp wave

03H:

Uniform gray level (100% white)

04H:

Uniform gray level (variable level)

05H:

Color bar (RGB bayer)

Others:

Black