CAUTION: First, disconnect the vacuum

cleaner from the electrical outlet.

1.

Turn the unit over and remove

the bottom plate (see "How to

Remove Bottom Plate").

2.

Remove the brush roll and the

worn or broken belt from the

brush roll pulley and the motor

drive shaft (diagram 13).

3.

Loop the new belt around the

motor drive shaft and the brush

roll (diagram 14).

4.

Reinstall the brush roll back into

the housing. Turn the brush roll by

hand, making sure the belt is not

twisted and all rotating par ts

move smoothly (diagram 15).

5.

Reinstall the bottom plate (see

"How to Install Bottom Plate").

NOTE: To ensure maximum cleaning

efficiency, the belt should be checked

regularly to be sure it is in good con-

dition. Check to see if the belt is

stretched, cracked, or if excessive

slipping has occurred. Replace if

needed.