beautypg.com

Optional piping for circulation systems – Rinnai R98LSE-ASME User Manual

Page 25

background image

VA Series Outdoor LS Manual

25

Optional Piping for Circulation Systems

This is not an engineered drawing, it is intended only as a guide and
not as a replacement for professionally engineered project drawings.
This drawing is not intended to describe a complete system, it is up
to the contractor/engineer to determine the necessary components
for and configuration of the particular system being installed. The
drawing does not imply compliance with local building code
requirements. It is the engineer/contractor responsiblity to ensure
the installation is in accordance with all local building codes. Confer
with local building officials before installation.

Pressure Relief Valve

3/4" Ball Valve

3/4" Union

Check Valve

S

Pressure Regulator

Circulating Pump

Solenoid Valve

Boiler Drain Valve

KEY

Minimum 3/4" Hot Water

Supply Line

Building Fixture Outlets

(Optional)
2-6 Gallon
Storage Tank

(To eliminate cold water
sandwich effect caused by
frequent On/Off operation)

Note:

Water heater outlet temperature
cannot be adjusted when
circulation pump is running.

QTY

1

1

Expansion Tank

Rinnai

Water Heater

Rinnai
Equipment List

Rinnai
Water Heaters

RIK-KIT (Optional)
(3/4" Fittings Include:
2 Unions, 2 Ball Valves,
2 Drain Valves and
1 Pressure Relief Valve.)

3/4" Gas Connection

Gas Supply

PLEASE NOTE THIS PIPING

ARRANGEMENT REDUCES

RESIDENTIAL AND COMMERCIAL

WARRANTY TO THE FOLLOWING:

3 Years On Heat Exchanger

3 Years On Parts

(Full warranty will be maintained if an

on-demand recirculation

system is incorporated.

Refer to the Limited Warranty.)

Minimum 3/4 " Cold Water Supply Line

For this application:

Pump should be controlled by an Aquastat,
Timer or Combination Aquastat and Timer.

Pump to be sized to maintain circulation
loop temperature.

A minimum of 3 GPM flow is recommended
for the circulation system.

The pump should be sized to overcome the
pressure loss through the Rinnai water
heater, supply and return plumbing. Refer -
ence the Rinnai Hot Water System Design
Manual, Pump Sizing for Circulation.

Pump to be of bronze or stainless construc -
tion.