beautypg.com

Rinnai R98LSE-ASME User Manual

Page 18

background image

18

VA Series Outdoor LS Manual

Clearances

from

Appliance

1. Identify the installation location and confirm that

the installation will meet all required clearances.

2. Securely attach the water heater to the wall using

any of the holes in the wall installation brackets
which are at the top and bottom of the water
heater. Ensure that the attachment strength is
sufficient to support the weight. Refer to the
weight of the water heater in the Specifications
section.

Attachment of the Water Heater

wall installation

brackets

to

Combustibles

to Non-

Combustibles

Top of
Heater

12 inches
(305 mm)

2 inches
(51 mm)

Back of
Heater

0 (zero) 0

(zero)

* 0 (zero)

Front
(Panel)

24 inches
(610mm)

Front
(Exhaust)

24 inches
(610mm)

24 inches
(610 mm)

Sides of
Heater

6 inches
(152 mm)

1/8 inches
(3.2 mm)

Floor/
Ground

12 inches
(305 mm)

2 inches
(51 mm)

to side

to front

to top

to floor/ground

* The clearance for servicing is 24 inches in front
of the water heater