beautypg.com

Switching characteristics, Test circuit – Renesas HD74CBT1G125 User Manual

Page 4

background image

HD74CBT1G125

Rev.1.00 Apr 07, 2006 page 4 of 6

Switching Characteristics

(Ta =

40 to 85°C)

V

CC

= 4.0 V

Item Symbol

Min

Max

Unit

Test

conditions

FROM

(Input)

TO

(Output)

Propagation delay time

*1

t

PLH

t

PHL

0.35 ns

C

L

= 50 pF

R

L

= 500

A or B

B or A

Enable time

t

ZH

t

ZL

5.5 ns

C

L

= 50 pF

R

L

= 500

OE

A or B

t

HZ

4.5

Disable time

t

LZ

4.5

ns

C

L

= 50 pF

R

L

= 500

OE

A or B

V

CC

= 5.0

±

0.5 V

Item Symbol

Min

Max

Unit

Test

conditions

FROM

(Input)

TO

(Output)

Propagation delay time

*1

t

PLH

t

PHL

0.25 ns

C

L

= 50 pF

R

L

= 500

A or B

B or A

Enable time

t

ZH

t

ZL

1.6 4.9 ns

C

L

= 50 pF

R

L

= 500

OE

A or B

t

HZ

1.0 4.2

Disable time

t

LZ

1.0 4.8

ns

C

L

= 50 pF

R

L

= 500

OE

A or B

Note: 1. The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and

the specified load capacitance, when driven by an ideal voltage source (zero output impedance).

Test Circuit

OPEN

S1

C

L

= 50 pF

*1

500

Load circuit for outputs

Symbol

t / t

PLH

PHL

t / t

ZH

HZ

t / t

ZL

LZ

S1

OPEN

OPEN

7 V

500

See under table

GND

Note: 1. C

L

includes probe and jig capacitance.