Temperature controller installation – Rinnai RC98HPE User Manual
Page 34

34
Manual - Rinnai Condensing Water Heaters
Temperature Controller Installation
• The controller should be out of reach of small
children.
• Avoid locations where the controller may become
hot (near the oven or radiant heater).
• Avoid locations in direct sunlight. The digital
display may be difficult to read in direct sunlight.
• Avoid locations where the temperature controller
could be splashed with liquids.
• Do not install in locations where it can be adjusted
by the public.
Configurations
A maximum of 4 temperature controllers, including 
wired and wireless, can be installed for a water heater 
or bank of water heaters. Controllers can only be 
wired in parallel. Controllers cannot be wired in 
series. 
The 4 temperature controllers can consist of multiple 
MC-91’s or MC-502RC’s but only 1 BC-100V and only 
1 MC-100V. 
Any one of the 5 types of controllers can be installed 
by itself and still operate the water heater. All 
functions will be available with the exception that the 
clock function on the BC-100V will only be available if 
an MC-100V is also connected. 
If 4 MC-91’s are installed, simultaneously press the 
Priority and On/Off buttons on the fourth controller 
until a beep sounds. 
The table to the right shows some of the possible 
combinations of controllers. 
Cable Lengths and Size
The cable for the temperature controller should be a 
non-polarized two-core cable with a minimum gauge 
of 22 AWG. The maximum cable length from each 
controller to the water heater depends on the total 
number of wired controllers connected to the water 
heater. 
MC-91 + MC-91 + MCC-91 MC-502RC
MC-91 + MCC-91 + MC-502RC MC-502RC
MCC-91 + MC-502RC + BC-100V
MC-100V
MC-91 + MC-502RC + BC-100V
MC-100V
MC-91 + MC-91 + MC-502RC BC-100V
MC-91 + MC-502RC + MC-502RC
MC-100V
+
+
+
+
+
+
Number of Wired
Controllers
Maximum Cable Length for each
Controller to Water Heater
1
328 ft (100 m)
2
164 ft (50 m)
3 or 4
65 ft (20 m)
Location
Controllers
Wire controllers in parallel
Indoor models have their controller built into the front panel. A kit is available that allows the integrated controller 
to be removed and used as a remote controller. Additional controllers can also be installed. 