Technical details – Rinnai HD70e User Manual
Page 10
10
TECHNICAL DETAILS
Infinity Model
Infinity 32e
HD70e
Units
Installation
External
External
Nat Gas Press Low
1.8
1.8
mbar
Nat Gas Press High
7.4
7.4
mbar
LPG Press Low
3.5
3.5
mbar
LPG Press High
17.6
17.6
mbar
Height
600
600 mm
Width
470
470 mm
Depth
244
220 mm
Weight
29
29
kg
Flue System
Temp. Range Controllers
37
°
C -
40, 43, 50, 55*
60, 65, 75
40, 43, 50, 55
60, 65*, 75, 85
55
°
C 37
°
C - 65
°
C deg
C
Ignition
Direct Electronic Ignition
Gas Consumption Low
Nat Gas
5.7
5.7
kW
LPG
5
5.4
.4 kW
Gas consumption High
Nat Gas
69
69
kW
LPG
69
69
kW
Max Flow raised 33C
24
24
L/min
Min Operation Flow
2.4**
L/min
Water Pressure Nom.
1.4 - 8.3
bar
Power Supply
230 V / 50 Hz
Electric Consumption
83
83
Watts
Forced Exhaust
Temp. Range without
Controllers
* Factory Setting
** Minimum operation flow based on temperature setpoint and
inlet conditions.
deg C