4 twisted pair data port specifications, 5 fiber optical port specifications – RuggedCom RS900G User Manual
Page 15
15
2008 RuggedCom Inc. All rights reserved
Rev104
3.4 Twisted Pair Data Port Specifications
Data Port
Media
Distance
Connector Type
10/100 Mbps
Cat 5 UTP or STP
100m
RJ45
3.5 Fiber Optical Port Specifications
For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for
Gigabit fiber optical communications. The following table details fiber optic specifications based on
the order code / transceiver selected at time of ordering.
Order
Code
Mode /
Connector
Tx
λ
λ
λ
λ
(nm)
Cable
Type
2
Tx Pwr
(dBm)
3
(Min/Max)
Rx
Sensitivity
(dBm)
3
Rx
Saturation
(dBm)
3
Typical
Distance
1
(km)
2LCMM
MM / LC
850
50
µ/125
-9.5 / -4
-20
0
0.5
2LC10
SM / LC
1310
9
µ/125
-9.5 / -3
-22
-3
10
2LC25
SM / LC
1310
9
µ/125
-5 / 0
-22
-3
25
2SC10
SM / SC
1310
9
µ/125
-10 / -3
-22
-3
10
2SC25
SM / SC
1310
9
µ/125
-7 / -3
-24
-3
25
SFP
MM / LC
850
50
µ/125
-8.5 / -4
-22
-3
0.5
SFP
SM / LC
1310
9
µ/125
-9 / -3
-24
0
10
SFP
SM / LC
1310
9
µ/125
-7 / -3
-26
-3
25
SFP
4
SM / LC
1550
9
µ/125
-5 / 0
-26
0
50
SFP
4
SM / LC
1550
9
µ/125
0 / 5
-26
0
80
SFP
SM / SC
Simplex
1310
9
µ/125
-9 / -3
-22
-3
10
SFP
4
SM / SC
Simplex
1490
9
µ/125
-9 / -3
-22
-3
10
NOTES:
1.
Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
2.
All cabling is duplex type unless otherwise specified.
3.
All optical power numbers are listed as dBm averages.
4.
These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20°C
to +85
°C operation only.