HD74LV2GT66A

Rev.2.00, Oct.17.2003, page 5 of 9

Switching Characteristics

V

CC

= 3.3 ± 0.3 V

Ta = 25°C

Ta = –40 to 85°C

Item

Symbol

Min

Typ

Max

Min

Max

Unit

Test

Conditions

FROM

(Input)

TO

(Output)

1.5

6.0

10.0

C

L

= 15 pF

Propagation
delay time

t

PLH

t

PHL

4.0

9.0

12.0

ns

C

L

= 50 pF

IN/OUT
or OUT/IN

OUT/IN
or IN/OUT

4.0

11.0

15.0

C

L

= 15 pF

Enable time

t

ZH

t

ZL

6.0

18.0

22.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

5.0

11.0

15.0

C

L

= 15 pF

Disable time

t

HZ

t

LZ

8.0

18.0

22.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

V

CC

= 5.0 ± 0.5 V

Ta = 25°C

Ta = –40 to 85°C

Item

Symbol

Min

Typ

Max

Min

Max

Unit

Test

Conditions

FROM

(Input)

TO

(Output)

1.0

4.0

7.0

C

L

= 15 pF

Propagation
delay time

t

PLH

t

PHL

3.0

6.0

8.0

ns

C

L

= 50 pF

IN/OUT
or OUT/IN

OUT/IN
or IN/OUT

3.0

7.0

10.0

C

L

= 15 pF

Enable time

t

ZH

t

ZL

5.0

12.0

16.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

4.0

7.0

10.0

C

L

= 15 pF

Disable time

t

HZ

t

LZ

6.0

12.0

16.0

ns

C

L

= 50 pF

C

IN/OUT
or OUT/IN

Operating Characteristics

C

L

= 50 pF

Ta = 25°C

Item

Symbol

V

CC

(V) Min

Typ

Max

Unit

Test Conditions

Power dissipation
capacitance

C

PD

5.0

4.0

pF

f = 10 MHz