5. Connection Procedure (See Figure 3)

REJ10J1864-0200 Rev.2.00

Page 2 of 4

Apr 16, 2010


The procedure for connecting the R0E53034ECFK60 is shown
below.

(1) Mount the NQPACK048SD on the user system.

(2) Attach the YQPACK048SD on the NQPACK048SD.

(3) Secure the four corners of the YQPACK048SD with the

YQ-GUIDEs.

Do NOT use the screws included with the

YQPACK048SD for fixing the YQPACK048SD.

Do NOT use the screwdriver included with the

NQPACK048SD for fixing the YQ-GUIDEs. That is

used only for the HQPACK048SD.

(4) Mount the R0E53034ECFK60 on the YQPACK048SD.

(5) Attach the flexible cable R0E001000FLX10 of the

emulator to the R0E53034ECFK60.

(1)

(2)

(3)

(4)

(5)

Use a slotted screwdriver.

●: No.1 pin
Be sure to align the pins.

48-pin 0.5mm pitch

foot pattern

YQPACK048SD

NQPACK048SD

YQ-GUIDE (×4)

R0E53034ECFK60

Flexible cable

R0E001000FLX10

Figure 3 Connection procedure of the R0E53034ECFK60