Regency Freestanding Woodstove

4

This is a copy of the label that accompanies
each Regency Freestanding Woodstove
(F2400M). We have printed a copy of the
contents here for your review.

SAFETY LABEL

NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.

HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

DO NOT REMOVE THIS LABEL

244

CERTIFIED TO COMPLY WITH JULY 1990

PARTICULATE EMISSION STANDARDS.

UNITED STATES ENVIRONMENTAL

PROTECTION AGENCY

MADE IN CANADA

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEPT

OCT

NOV

DEC

CAUTION

DA

TE OF MANUF

ACTURE

918-172b

rev. 10/03

LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION

MODEL: REGENCY MEDIUM FREESTANDING STOVE - F2400M
TESTED TO:

UL1482 / ULC S627 / UL 737

REPORT NO:219-S-02-2

THE F2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

F2400M WITH AIRMATE SHIELD

F2400M WITHOUT AIRMATE SHIELD

RESIDENTIAL INSTALLATION USING

SINGLE WALL CONNECTOR

MEASURE

FLUE

FROM

HEATER

CENTER-LINE

RESIDENTIAL INSTALLATION USING

SINGLE WALL CONNECTOR

SIDEWALL

A 457 mm / 18 in

D 762 mm / 30 in

BACKWALL

B 305 mm / 12 in

E 470 mm / 18.5 in

CORNER

C 165 mm / 6.5 in F 457 mm / 18 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - MOBILE HOME

SIDEWALL

A 380 mm / 15 in

D 685 mm / 27 in

BACKWALL

B 165 mm / 6.5 in

E 330 mm / 13 in

CORNER

C 152 mm / 6 in

F 444 mm / 17.5in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

SIDEWALL

A 380 mm / 15 in

D 685 mm / 27 in

BACKWALL

B 165 mm / 6.5in

E 330 mm / 13 in

CORNER

C 152 mm / 6 in

F 444 mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - ALCOVE

SIDEWALL

A 406 mm / 16 in

D 711 mm / 28 in

BACKWALL

B 280 mm / 11 in

E 444 mm / 17.5 in

CORNER

C 152 mm / 6 in

F 444 mm / 17.5 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - MOBILE HOME

SIDEWALL

A 380 mm / 15 in

D 685 mm / 27 in

BACKWALL

B 140 mm / 5.5 in E 304 mm / 12 in

CORNER

C 102 mm / 4 in

F 393 mm / 15.5 in

SIDEWALL

A 380 mm / 15 in

D 685 mm / 27 in

BACKWALL

B 140 mm / 5.5 in E 304 mm / 12 in

CORNER

C 102 mm / 4 in

F 393 mm / 15.5 in

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - RESIDENTIAL CLOSE CLEARANCE

INSTALLATION USING LISTED DOUBLE WALL

CONNECTOR - ALCOVE

SIDEWALL

G 380 mm / 15 in

I 685 mm / 27 in

BACKWALL

H 165 mm / 6.5 in

J 330 mm / 13 in

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.

FLOOR

PROTECTION*

F2400M WITHOUT

AIRMATE SHIELD

F2400M WITH

AIRMATE SHIELD

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING
INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED
STEEL CONNECTOR WITH LISTED UL103 HT FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID
FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR
PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A
COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR
THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT
TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

FRONT

BACK

L

K

M

SI

DE

SIDE

K 405 mm / 16 in
L 150 mm / 6 in
M 150 mm / 6 in

FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR
OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. IF INSTALLED
IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE MANUFACTURER
SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY
CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP
MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE
FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST
PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR (846-101)
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:

LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM: SECURITY MODEL S2100,

ICC EXCEL 2100, SELKIRK SENTINAL CF.
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER
PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL
SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS
AS SPECIFIED IN INSTALLATION INSTRUCTIONS.

MEASURE

FLUE

FROM

HEATER

CENTER-LINE

MANUFACTURED BY:

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4

SIDEWALL

G 380 mm / 15 in

I 685 mm / 27 in

BACKWALL

H 140 mm / 5.5in

J 304 mm / 12 in

2003

2005

2004

* In Canada, floor protection must
extend 18" (450mm) to the front
and 8" (200mm) to each side and
back of the stove.