Installation – Regency FREESTANDING WOODSTOVE2 F2400M User Manual

Page 18

background image

Regency Freestanding Woodstove

18

Blower/Fan (846-515)

1) Remove the two screws from the top of the

fan housing.

2) Slide the fan up into the rear heat shield.

3) After aligning holes, secure the fan to the

rear heat shield using the two screws
removed earlier.

CAUTION: The connection cord should

not be in contact with any hot sur-
faces. Do not route cord under or
in front of unit.

Read the operating instructions for the fan
before using. See Page 19.

INSTALLATION

Ground

Fan

Fan

Ground

Green

Neutral

Live

White

Fan

Switch

Manual/

Auto

Switch

Black

Black

High

(Black)

Low

(Red)

Black

Fan Thermodisc

(normally open)

120V AC

60 Hz

Blower/Fan Wiring Diagram

CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged (ground-
ing) plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the ground-
ing prong from this plug.