Getting Started

Coaxial Cable Installation Precautions

• Do not bend the coaxial cable into less than a three-inch radius. Tighter bends can cause

shorts and can change the cable’s impedance.

• Do not install the coaxial cable where it will have a pulling tension greater than 15 pounds

during installation. After installation, make sure there is no tension on the cable.

• Use only round-headed staples. Any clamps or securing devices used with coax should grip

the cable evenly about the circumference without crushing the cable. Flat staples can damage
the coaxial cable.

• Do not expose the coaxial cable to a temperature greater than 176 degrees Fahrenheit. Keep

the cable away from heating vents and water heaters.

• The cable jacket withstands most outdoor environments. However, you must seal the

connections and splices against water entry.

Specifications

VHF Range

54-250 MHz

UHF Range

470-806 MHz

VHF Gain

18 dB

UHF Gain

15 dB

AC Adapter

Included

DC Power Injector

Included

RG59 Cable

Included