Chapter 11, 3 remote control connection & operation – Rackmount Solutions CYBER VIEW RP-817QD User Manual
Page 36
The device may be controlled via the male type 9 pin D-sub/RS-232 connector (#13) from a RC-5002 keypad, terminal or
computer using ASCII code.
Note: Please power off the unit before connecting the Remote Control keypad.
1. Pin assignment of the male type 9 pin D-sub connector:
When a computer is used to control this device through a RS-232 port, pin 6, 7, 8, and 9 must be disconnected to
prevent connecting the VCC and GND signals from the device to the computer. A RS-232 port only uses pin 1, 2,
and 3 for control signal transmission.
2. A terminal or computer can be connected to the male type 9 pin D-sub connector on the real panel from it RS-
232 port to control this device using standard, uppercase ASCII codes.
2.1 The ASCII command codes for the quad are listed in the table below. The transmission protocol is 1200-
baud rate, 8 data bit, 1 start bit, 1 stop bit, and no parity.
Pin Assignment for Remote Control Connector
1
GND
4
NC
7
VCC
2
RX
5
NC
8
GND
3
TX
6
VCC
9
GND
11.3 Remote Control Connection & Operation
Chapter 11
1 2 3 4 5
6 7 8 9
Function
ASCII Command Code
Quad Screen Display
E
CH 1
A
CH 2
B
CH 3
C
CH 4
D
Freeze *1
EA, EB, EC, ED
Auto Switching Sequence
F
VCR/Live
G
Key Lock *2
H
Setup Menu *3
GH
Text Select Down *4
(GH) A
Text Select Up
(GH) B
Cursor Left
(GH) C
Cursor Right
(GH) D
Alarm Reset
I
P.32