Command No.
Command Descriptions
79H:
EFFCT[7
0]
[Image effect selection] Initial data: EFFCT[7..0] = 0
Sets the image effect.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
00H:
No effect (Original video)
01H:
11bit gradation
02H:
10bit gradation
03H:
9bit gradation
04H:
8bit gradation
05H:
7bit gradation
06H:
6bit gradation
07H:
5bit gradation
08H:
4bit gradation
09H:
3bit gradation
0AH:
2bit gradation
0BH: 1bit gradation
0C to FEH: No function
FFH:
MSB-LSB reverse
80H:
E2P[7
0]
[EEPROM control] Initial data: E2P[7
0] = 0
Sets the image effect.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7~D2:
No function
Always set as “000000”
D1:
Register synchronous update with the EEPROM data
0: Prohibited
1: Accept
D0:
Write control to the EEPROM
0: Prohibited
1: Accept
F0H:
OUTSEL[7
0]
[EEPROM control] Initial data: OUTSEL[7
0] = the value of C0H
Sets the image effect.
D[7..0]
D7
D6
D5
D4
D3
D2
D1
D0
D7~D4:
No function
Always set as “000000”
D3~D0:
The
signals
of
the
power/IO
connector selection
Please refer to “The Signals of the Power/IO Connector”