beautypg.com

Ricoh Small Cubic Type 5.0 Mega Pixel CCD Monochrome PoCL Camera Link Camera FV-L500B1 User Manual

Page 28

background image


28/31

FV-L500B1
User’s Guide Rev. 1.01


Command No.

Command Descriptions

26H:

PWR[7

0]

27H:

PWR[15

8]

[Effective line numbers in the variable partial scanning]

Initial Data: PWR[15

0] = 2058, Data Range: 0 to 2058

This sets the number of the total effective lines (image height) in the variable partial scanning mode.

Notes:

1. The value replaces by 2058 automatically when the value set greater than 2058.

2. The camera works with full scanning mode when the value of (PSR[ ] + PWR[ ]) is greater than 2058.

28H:

DLY[7

0]

[Delay time for the trigger] Initial Data: DLY[7

0] = 0, Data Range: 0 to255

Sets the delay time from the trigger input signal to the start of the exposure.

Delay time (us) = 128 x CLK x DLY[7

0] = 2.000 (us) x DLY[7

0], where CLK = pixel clock

30H

PGA[7

0]

[CDS gain] Initial Data: PGA[7

0] = 0, data range: 0 to 255

Sets the CDS gain (programmable analog gain).

CDS gain = 11.1 + 0.0359 x (PGA[7..0] x 2 + GOFS[7..0]) (dB)

*GOFS[7...0]: The gain offset (The value of the address 32H)

31H

DGB[7

0]

[Digital gain] Initial Data: The factory adjusted value, Data Range: 0 to 255

Sets the digital gain.

Output level = (input level – CLAMP[7

0] x 16 – (CDS_CLAMP_L[9..0] + CDS_CLAMP_R[9..0]) / 2) x

(1 + (DGB[7..0] + GOFS[7..0]) / 128) + CLAMP[7..0] X 16 +

(CDS_CLAMP_L[9..0] + CDS_CLAMP_R[9..0]) / 2

*CLAMP[7...0]: clamp level (command no. 38H)

*GOFS[7...0]: gain offset (command no. 32H)

*CDS_CLAMP_L[9...0]: CDS clamp left (command no. CC-CDH)

*CDS_CLAMP_R[9...0] CDS clamp right (command no. CE~CFH)

32H

GOFS[7

0]

[Gain offset] Initial Data: The factory adjusted value, Data Range: 0 to 255

38H:

CLAMP[7

0]

[Clamp level] Initial Data: CLAMP[7

0] = 0, Data Range: 0 to 31

This sets the clamp level value of the black level.

Clamp level (Left) = CLAMP[7..0] x 16 + CDS Clamp (Left)

Clamp level (Right) = CLMAP[7

0] x 16 + CDS Clamp (Right)

The value replaces by 31 automatically when the value set greater than 31.

3EH: TP0[7

0]

3FH:TP0[9

8]

[Test pattern level] Initial data: 4095, data range: 0 to 4095

Sets the output level of the test pattern 4: Raster (variable level) in 10-bit output format.