Solenoid Valve

Burnt Coil

Valve does not activate.

Replace.

Blocked

No pressure leaving the valve.

Clean.

Stuck Closed Or Open

Dirty plunger.

Clean and install
external filters.

Timer

Wrong Timer Settings

System will not come on.

System only stays on for a few
seconds.

Reduce the off cycle.

Increase the on cycle.

Burnt Timer

The timer lights are not on.

Burnt smell from inside the
control panel.

Replace.

Panel
Regulators

Damaged Diaphragm

Loss in air pressure.

No air pressure.

Uncontrolled air pressure.

Repair.

AFE Nozzle

Stuck Cleaning Needle

Nozzle does not clean itself.

Lubricate seal and shaft
of needle.

Nozzle Drips

Water on the floor.

Replace damaged

o-ring on end of needle.