PERFORMANCE RATINGS

MODEL QTXEN110S
VENTILATOR

AMPS

Model

Amps*

QTXEN110S

0.3

WEIGHT

Model

Shipping

Weight
QTXEN110S 12.2 lbs.

*

Total connected load

AIR FLOW PERFORMANCE

MODEL QTXEN110S

TYPICAL SPECIFICATION

Ceiling Ventilator shall be NuTone Model QTXEN110S.
The unit will have a control that will automatically turn fan ON

when humidity increase is rapid to moderate (user adjustable), or

when humidity is higher than user-adjustable set-point (50%-80%

Relative Humidity), or when supply power is cycled from ON (for

more than a second) to OFF (for less than a second) and back

ON. It shall be user-adjustable to turn OFF 5 to 60 minutes after

humidity has stabilized and is below user-adjustable set-point,

or after manually initiated by supply power cycling.
Ceiling Ventilator shall have corrosion resistant galvanized steel

housing with four-point mounting capability. It shall be ducted to

a roof or wall cap using 6” round ductwork.

Blower assembly shall be removable, have a centrifugal-type blower

wheel and a permanently lubricated motor designed for continuous

operation.
Non-metallic damper/duct connector shall be included.
Air delivery shall be no less than 110 CFM and sound level no greater

than 0.7 Sones. All air and sound ratings shall be certified by HVI.
Ceiling Ventilator shall be Energy Star® qualified and have an energy

efficient permanent split capacitor motor.
Ceiling Ventilator shall be U.L. Listed for use over bathtubs and

showers when connected to a GFCI protected branch circuit.

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0

10

20

30

40

50

60

70

80

90 100 110 120 130

Air flo w (cfm )

P

s

(

in

.

w

.g

.)

HVI-2100 CERTIFIED RATINGS comply with new

testing technologies and procedures prescribed

by the Home Ventilating Institute, for off-the-shelf

products, as they are available to consumers.

Product performance is rated at 0.1 in. static

pressure, based on tests conducted in a state-of-

the-art test laboratory. Sones are a measure of

humanly-perceived loudness, based on laboratory

measurements.

HVI PERFORMANCE

Static

Fan

Model

Pressure (Ps) CFM Sones Watts

QTREN110S

0.10

110

0.7

33.5

0.25

90