17

If LAM was exposed to salt water it should be rinsed in
fresh water and dried outside at no more than 55

o

C.

Long-term storage

When preparing for long-term storage, cover the external
metal surfaces of LAM with protective lubricant. Each 4
(four) years old layer of lubricant should be removed and
new layer be applied.

To remove old layer of lubricant:
-

Wipe LAM with clean dry cloth,

-

Degrease metal surfaces of LAM with benzene
moistened cloth,

-

Dry LAM out-of-doors.

Do not touch unit’s metal surfaces with fingers after

cleaning.

To apply new layer of lubricant:
-

Within two hours from the cleaning apply an
even 0.2-0.5 mm thick layer of lubricant on
metal surfaces with a brush.

-

Do not cover plastic parts.