beautypg.com

NuTone LA-174 User Manual

Built-in electronic chime, Model: la-174, Installation hints

background image

INSTALLATION HINTS

• This Door Chime is recessed into the wall. The white louvered grille

is flush-mounted to the wall surface and may be painted.

• IMPORTANT: If the door chime is connected to a NuTone Radio-

Intercom System, the chime tones will be heard at all inside and
outside speaker locations (chime will not sound at door speaker).
The Door Chime must be wired in accordance with the Chime-To-
Intercom information that is included in this literature.

• If a NuTone Radio-Intercom System is not used, a door speaker

may be installed at the outside of the front door
so chime tones will be heard at that location.

• Use the NuTone transformer that has been supplied with the door

chime.

LOCATION

• Select a central location so the door chime will be heard throughout

the house.

• Select pushbutton location(s). This door chime can accommodate

up to three (3) door operations.

MOUNTING THE CHIME

Required cutout dimensions: 5

3

8

" wide x 7

1

4

" high.

Housing: 2

1

4

" deep

Refer to Figure 2. Locate wall stud and prepare wall opening at
desired location.

WIRING

IMPORTANT: Be certain all wiring complies with local and

state codes.

Disconnect the house power when installing the transformer.

Keep electricity off until all wire connection have been made.

When securing the wiring to wall studs or ceiling joist, avoid

possible shorts that may occur if staples or clips penetrate the
protective wiring insulation.
1. Mount the supplied transformer to any junction or panel box.

Connect the white and black wires from the transformer to the
matching colors of house supply wires. Use approved wire
connectors to make all connections.

2. Refer to Figure 1. Run 18-2 gage wire from the transformer and

pushbutton(s) to the chime location.

3. If applicable, run NuTone IW-2 cable (No.22 twisted pair) from the

intercom master station to the chime location.

4. If applicable, run NuTone IW-2 cable (No. 22 twisted pair) from

remote speaker(s) to door chime location.

5. Pull wires through knockout in housing. Position the housing flange

flush to the finished wall surface and carefully secure the housing
with screws. CAUTION: The printed circuit board is fragile; DO
NOT use nails or hammer.

MAKING CONNECTIONS

1. Refer to Figure 1. Make wire connections to terminals shown as

applicable.

2. Upon completion of installation, check whether chime is functioning

properly by pressing each door pushbutton, if the chime does not
operate, recheck your installation and the pushbutton(s) for poor
contact or loose connections.

Built-In Electronic Chime

MODEL: LA-174

FIGURE 1

1ST DOOR

WIRE
CONNEC-
TORS

GREEN
(COM)

YELLOW
(TRANS)

120/110 VOLT
AC WIRING

16 VOLT, 10 VATT TRANSFORMER

2ND DOOR

3RD DOOR

18-22 GA.
INSLUATED
WIRE

WIRE
CONNECTOR

TRANSFORMER HOOK-UP

18-22 GA. INSULATED WIRE.
MAX. OF 100 FT. EACH WIRE
FOR 22 GA.

PRINTED CIRCUIT BOARD

OPTIONAL CONNECTIONS

HOOK-UP TO RADIO-INTERCOM

Radio-Intercom connections to
provide chime functions in
intercom speakers. See Standard
Chime-to-intercom section for
specific connections.

18-22 GA. INSULATED WIRE

NUTONE IW-2

NUTONE IW-2

HOOK-UP TO EXTENSION
SPEAKERS (MAX. 3)

Use NuTone IW-2 (22 GA
Insulated 2-Conductor cable) –
200 Feet Maximum. Connect
Speaker to “EXTENSION
SPKR.” No. 1 and No. 2.

INSTALLATION INSTRUCTIONS