background image

Chapter 4

Signal Connections

PCI-6110E/6111E User Manual

4-14

© National Instruments Corporation

Caution:

Exceeding the maximum input voltage ratings, which are listed in
Table 4-2, can da
mage the 611X E board and the computer. National
Instruments is

NOT

liable for any damages resulting from such signal

connections.

Figure 4-6 shows signal connections for three typical digital I/O
applications.

Figure 4-6. Digital I/O Connections

Figure 4-6 shows DIO<0..3> configured for digital input and
DIO<4..7> configured for digital output. Digital input applications
include receiving TTL signals and sensing external device states such
as the switch state shown in Figure 4-6. Digital output applications
include sending TTL signals and driving external devices such as the
LED shown in Figure 4-6.

!

LED

+5 V

TTL Signal

+5 V

DIO<4..7>

DIO<0..3>

DGND

Switch

I/O Connector

611

X E Board