DO NOT USE ANY MAKESHIFT MATERIALS

DURING INSTALLATION.
1.
Move the stove into position with the flue centered,
midpoint between two joists to prevent having to cut
them. Use a plumb bob to line up the centre.
2. Cut and frame an opening in the roof to provide a 2"
clearance between the outside of the chimney and any
combustible material.

DO NOT FILL THIS SPACE WITH ANY TYPE

OF MATERIAL.
Nail headers between the joist for extra support.
Firestop spacers must be placed on the bottom of each
framed opening in any floor or ceiling that the chimney
passes through.
3. Hold a plumb bob from the underside of the roof to
determine where the opening in the roof should be. Cut
and frame the roof opening to maintain proper 2" clear-
ances.

ADDING CHIMNEY SECTIONS

Add chimney sections, twist lock-
ing (clockwise) securely, to the re-
quired height. The chimney must
extend, at least, 3 feet above its
point of contact with the roof and
at least 2 feet higher than any
wall, roof or building within 10 feet.
FIGURE 6. If your chimney sys-
tem is enclosed within the attic
area, a rafter radiation shield is
required.

PEDESTAL MODELS
OUTSIDE AIR

If possible connect the
air intake at the
pedestal's back or
bottom to the outside
with a 4 inch (100mm)
diameter fresh air kit
available at your
Napoleon/Wolf Steel
Ltd. dealer. Follow
detailed instructions
under "Mobile Home
Outside Air".

MOBILE HOME

INSTALLATION

ONLY PEDESTAL MODEL 1100 IS APPROVED

FOR INSTALLATION IN MOBILE HOMES. DO

NOT INSTALL IN A ROOM USED FOR SLEEP-

ING.

The pedestal base must be firmly bolted to the floor
with 1/4 inch lag bolts. Minimum clearances to
combustibles are as shown in FIGURE 8.

VENTING

Connect the stove to a
chimney system using
a listed double wall
c o n n e c t o r ,
Security DL6 in
Canada or Dura Vent
Plus DVL
in the U.S.A.
Use chimney system
listed to ULC S629 in
Canada or a Dura Vent
Plus chimney system
in U.S.A.
The chimney must be
installed in accordance
with the manufactur-
er's instructions. Use
only specified compo-
nents with no substitu-
tions. The chimney
and pipe must extend
at least 8 feet above
the stove and 3 feet above the highest point of the roof.
Install a rain cap at the top which will not impede the
smoke exhaust. The chimney must be supported at
the ceiling or roof so that its weight does not rest on
the stove.
It must be installed between ceiling joists, with radia-
tion shield and roof flashing, so that the structural
strength, insulation and waterproof qualities of the home
are not lessened. Seal with silicone to maintain a va-
pour barrier at the chimney and outside air pipe
penetrations.

UNDERSIDE OF JOIST

FIRESTOP SPACER -

HEADERS

BACK WALL

23"

9"

6"

SIDE WALL

14"

2"

11 1/2"

BACK WALL

45 °

SIDE WALL

OUTSIDE AIR CONNECTION

HEARTH PAD

THROUGH WALL OR FLOOR

STOVE BOLTED

TO FLOOR

CEILING SUPPORT

TRIM COLLAR

ROOF FLASHING

MOBILE HOME

RADIATION SHIELD

RAIN CAP

FIGURE 5