Stove installation – Napoleon Fireplaces EPA 1900 User Manual
Page 5

5
W415-0282 / 09.05.01
INSTALLING THE LEGS
To avoid being damaged during shipping, the stove
has been bolted to the pallet and must be unbolted
before the stove can be installed.
1. Remove the 4 nuts and
washers from the underside
of the pallet.
2. Lift the stove up and away
from the pallet to clear the
threaded studs sticking
through the pallet. Place the
stove on its back onto a pro-
tective surface such as a car-
pet or blanket to avoid
scratches during leg installa-
tion.
3. Remove the four additional nuts from each of the
four studs.
4. Use four of the nuts and washers removed above to
install the legs as illustrated in FIGURES 2a & 2b.
5. Lift the stove up and gently set down on all four legs.
Do not pivot unit up on its legs, as this could result in
damage to the legs.
ALCOVE INSTALLATION
Model 1100 only may be installed, using a listed dou-
ble wall connector, such as Security DL6 in Canada,
the Simpson Duravent Plus DVL in the USA or an
equivalent double wall connector, into an alcove hav-
ing a depth of no more than 4 feet and a height of at
least 7 feet. The minimum clearances are as shown
in FIGURE 3.
STOVE INSTALLATION
If the stove is to be installed on a
combustible floor, it must be
placed on a approved non-com-
bustible hearth pad, that extends
8" (200mm) beyond the stove
sides and back, and 18" (455mm)
to the front.
M a i n t a i n t h e s e m i n i m u m c l e a r a n c e s t o
combustibles with a single wall chimney connec-
tor*:
CHIMNEY CONNECTION
Vent the stove into a masonry chimney or an approved,
insulated solid-fuel stainless-steel chimney with as short
and straight a length of six-inch (150mm) diameter
smoke pipe as possible. Connection to a masonry chim-
ney must be by a metal or masonry thimble cemented
in place. An insulated stainless steel chimney must be
supported at the ceiling or roof and its installation must
comply with its manufacturer's instructions.
THE TOTAL SMOKE PIPE LENGTH SHOULD
NOT EXCEED 40% OF THE CHIMNEY
HEIGHT ABOVE THE STOVE.
All smoke pipe must slope slightly upwards
a minimum of 1/4" per foot (6mm/0.3m) and
all connections must be tight and secured
by three sheet metal screws equally spaced.
An uninsulated smoke pipe shall not pass
through an attic, roof space, closet or simi-
lar concealed space, or through a floor, ceil-
ing, wall or partition, or any combustible
construction.
STOVE INSTALLATION
FIGURE 2B
FIGURE 2A
FIGURE 3
*ALL CLEARANCES CAN BE REDUCED WITH SHIELDING SUCH AS DOUBLE WALL
CHIMNEY CONNECTORS ACCEPTABLE TO THE LOCAL AUTHORITIES.
1100/1100L
1400/1400L
1900
A 12" (305mm)
12" (305mm)
22" (560mm)
B 10" (255mm)
12" (305mm)
12" (305mm)
C 6" (150mm)
6" (150mm)
8" (205mm)
D 21" (535mm)
21" (535mm)
31" (790mm)
E 13" (330mm) 16.5" (420mm) 16.5" (420mm)
F 16" (405mm) 16.5" (420mm)
19" (485mm)
FIGURE 4B
FIGURE 4A