Figure 39. thermostat wiring a/c ready models – Nordyne Forced Air Gas and Oil Furnace M1M User Manual
Page 32
![background image](/manuals/192412/32/background.png)
32
Figure 39. Thermostat Wiring A/C Ready Models
Figure 37. Coil Cavity Damper (Non-Platinum Series Only)
Figure 38. Damper without Coil Cavity (Non-Platinum Series Only)
Rc
R
H
W
G
Y
Red
White
Green
Yellow
Red
White
Green
Grey
**
Thermostat
M1* A/C Ready
Furnace
Route Thermostat wire to intended Platinum
Series AC/HP location. Coil and secure extra
six feet of wire to home's undercarriage.
Platinum Ready Wiring
Rc
R
H
W
G
Y
Red
White
Green
Yellow
Red
White
Green
Grey
**
Thermostat
M1* A/C Ready
Furnace
Standard Wiring
This manual is related to the following products: