beautypg.com

Nordyne Forced Air Gas and Oil Furnace M1M User Manual

Page 18

background image

18

Figure 27. Typical Oil Piping for Above Ground (Single-Line) Supply

If fuel pump fails to lift oil, check for air

port plug and repeat priming procedure.

leaks and tighten all fuel fittings. Re-

prime fuel pump by injecting fuel oil into

optional (top) return port. Replace return

R

Top of Tank

8 ft.

Shut-off

Valve

Optional

Fuel

Filter

Alternate

Fuel Line

Entry

Optional

Return

Pressure

Gauge Port

Nozzle

Port

Inlet

Port

Air-Bleed

Valve

Return Port &

Internal By-Pass

Optional

Inlet

;;;;;;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;;;;;;

;;;;;;;;;;;;;;;;;;;;;;

Control

Panel

Oil

Furnace

On-Off-Fan

Switch

Floor Cavity

Oil-Gun

Burner

Floor

Flue Gas

Sampling

Hole

Drain

End of Oil Supply Line

3" to 5" Above

Bottom Drain

Guide pipe

Gauge

Vent with

Cap

2" Duplex

Bushing

2" Fill

3/8" Oil Supply Line

Note: Additional venting

may be required if tank

is filled rapidly.