SYMPTOM

PROBLEM

TEST SOLUTION

Remote wall switch
is in “OFF” position;
main burner comes
on when gas knob
is turned to “ON”
position.

Wall switch is mounted upside
down

- reverse.

Faulty valve.

- replace.

- replace.

Remote wall switch is ground-
ing.

- check for ground (short); repair ground or replace wire.

Remote wall switch wire is
grounding.

Carbon is being
deposited on, logs or
combustion chamber
surfaces.

Flame is impinging on the logs
or combustion chamber.

- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifi ce size as speci-
fi ed by the rating plate values.
- close mesh screens.

Air shutter has become blocked

- ensure air shutter opening is free of lint or other obstructions.