7

MODEL IDENTIFICATION CODE

Design Series

A = 80% Upflow/Horizontal
C = 92.1% / 95.1% Upflow/Horizontal
K = 80% Downflow
L = 92.1% / 95.1% Downflow
Q = 96.4+% AFUE Upflow/Horizontal

FG

T

080

C

23

Input Heating Capacity

060 = 60,000
080 = 80,000
100 = 100,000
120 = 120,000
140 = 140,000

S = Single Stage
T = Two Stage
M = Modulating

Gas Furnace

A

C = Standard
D = 90+% AFUE Low NOx

Cooling Airflow

23 = 2-3 Tons
24 = 2-4 Tons
35 = 3-5 Tons
45 = 4-5 Tons
V = VSB

7

Cabinet Width

A = 14.25
B = 17.50
C = 21.00
D = 24.50

B

SPECIFICATIONS

FG7TA/TK
MODEL NUMBERS

060C-23A1

080C-24B1

100C-24B1

100C-35C1

120C-35C1

140C-45D1

Input - Btuh (a)

60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 100,000 / 65,000 120,000 / 78,000 140,000 / 91,000

Heating Capacity - Btuh

48,000 / 31,200 64,000 / 41,600 80,000 / 52,000 80,000 / 52,000 96,000 / 62,400 112,000 / 72,800

AFUE

80.0

80.0

80.0

80.0

80.0

80.0

Blower D x W

10 x 6

11 x 8

11 x 8

11 x 10

11 x 10

11 x 10

Motor H.P. - Speed - Type

1/2 - BLDC

1/2 - BLDC

3/4 - BLDC

3/4 - BLDC

3/4 - BLDC

1 - BLDC

Motor FLA

6.2

6.2

8.7

8.7

8.7

11.7

Rated Ext. SP - In. W.C.

0.5

0.5

0.5

0.5

0.5

0.5

Temperature Rise Range - ºF

25-55

30-60

30-60

35-65

35-65

40-70

Shipping Weights

115lbs

110lbs

120lbs

125lbs

135lbs

155lbs

All models are 115 V, 60 HZ. Gas connections are 1/2" N.P.T.

AFUE= Annual Fuel Utilization Efficiency

1

Revision Level