Installation – Napoleon Fireplaces GDIZC-N User Manual
Page 5
5
W415-0223 / E / 03.05.09
36"
15
1
/
2
"
25"
10
9
/
16
"
5 ½"
AIR INLET
EXHAUST
4
15
/
16
"
15
1
/
2
"
11
5
/
8
"
7
3
/
8
"
3"Ø
44
7
/
8
"
3 SIDED BACKER PLATE
ALUMINUM TRIM
44
7
/
8
"
36
1
/
2
"
4 SIDED BACKER PLATE
ALUMINUM TRIM
Provide adequate ventilation air.
Provide adequate accessibility clearance for servicing
and operating the fi replace insert.
Never obstruct the front opening of the fi replace
insert.
Objects placed in front of the fi replace must be kept a
minimum of 48" away from the front face of the unit.
FIGURES 1a-c
Clean out ashes from the inside of the wood-burning fi replace.
Make sure that the chimney and wood-burning fi replace
are in a clean and sound condition and constructed of non-
combustible materials. If necessary have any repair work done
by a qualifi ed person before installing the insert. Remove the
existing fi replace damper or lock into an open position.
Using screws, attach the fi replace warning tag (W385-0199)
to the inside of the fi rebox of the fi replace into which the insert
is being installed.
The sheet-metal parts of the fi replace, in which the gas fi re-
place insert is to be installed, must not be cut.
If the wood-burning factory-built fi replace has no gas access
hole(s) provided, an access hole of 1½ inch or less may be
drilled through the lower sides or bottom of the fi replace in
a proper workman like manner. This access hole must be
plugged with non-combustible insulation after the gas supply
line has been installed.
Ensure that existing chimney cleanouts fi t properly.
The refractory, glass doors, screen rails, screen mesh and log
grates may be removed from the fi replace before installing
the gas fi replace insert.
Smoke shelves, shields and baffl es may be removed if at-
tached by mechanical fasteners.
The ventilation openings in the fi replace may be obstructed
by the backer plates, aluminium trim etc. but these parts are
not to be applied so as to have an airtight seal.
WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS
ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY
THE AUTHORITY HAVING JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME
FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU TOUT
AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE
REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR
LES AUTORITES
AYANT JURIDICTION.
W385-0199
14"
15
1
/
2
"
20
3
/
4
"
3 SIDED BACKER PLATE - FRONT VIEW
4 SIDED BACKER PLATE - FRONT VIEW
TOP VIEW
3 & 4 SIDED BACKER PLATES - SIDE VIEWS
INSTALLATION