AD V AN C E D F E AT U R E S
Security Bypass/Unbypass
(Security Bypass programmed? YES NO).
In high-security applications, zones may be bypassed (or unbypassed) only if a valid code is entered first, as follows:
1. Enter a User Code valid for bypass, then press
B
.
2. Press
B
then the zone number (or vice versa) to deactivate that zone.
Similarly, a bypassed zone may be unbypassed using the same procedure. (This feature available for GEM-P3200/9600 panels only).
Start Exit Time After Ringback
(for Commercial Burglary Systems only)
(Optional - Start Exit Time programmed? YES NO).
If your system reports to a central station, your panel may have been programmed to start exit delay after the central-station ringback
(verification) signal. Then, after arming, your system will communicate to the central station. After the central station acknowledges
receipt (ringback), exit delay will start. If ringback is not heard within about 30 seconds, a communication problem may exist; call for
service. Function 11 (Start Exit Time) may then be used to manually start the exit delay, however reporting capability may be
sacrificed. (If your system does not report or the ringback feature was not programmed, exit delay will start as soon as your code is
entered. Also note that if an exception window is programmed, and the closing is within that window, no ringback is provided. Ask your
alarm professional if this feature is enabled). (This feature available for GEM-P3200/9600 panels only).
Exit-Delay Restart
(Exit-Delay Restart programmed? YES NO).
On arming, the programmed exit delay will start. After the exit door has been opened and then closed, exit delay will change to 60
seconds. Thus, a long exit delay may be programmed, which will immediately be reduced to 60 seconds upon exiting. If re-entry occurs
during that 60 seconds, exit delay will restart once again (and only once again) at 60 seconds. If so programmed, re-entry within 60
seconds after exit delay has expired, will cause the alarm to sound a 2-second warning (in addition to the entry sounder) to remind the
user to disarm. (This feature available for GEM-P3200/9600 panels only).