Tables 7-1 and – National Instruments NI-488.2 User Manual
Page 69

Chapter 7
Interactive Control Utility
7-6
ni.com
Table 7-1. Syntax for Device-Level Traditional NI-488.2 Calls in Interactive Control
Syntax
Description
ibask option
Return configuration information where
option
is a mnemonic for
a configuration parameter.
ibclr
Clear specified device.
ibconfig option
value
Alter configurable parameters where
option
is mnemonic for
a configuration parameter.
ibdev BdIndx pad
sad tmo eot eos
Open an unused device;
ibdev
parameters are
BdIndx pad sad tmo
eot eos
.
ibeos v
Change/disable EOS message.
ibeot v
Enable/disable END message.
ibfind devname
Return unit descriptor where
devname
is the symbolic name of the device
template to use (for example,
dvm
).
ibloc
Go to local.
ibnotify mask
Start an asynchronous wait for selected events where mask is a hex or
decimal integer or a list of mask bit mnemonics (for example,
ibnotify
TIMO CMPL
).
ibonl v
Place device online or offline.
ibpad v
Change primary address.
ibpct
Pass control.
ibppc v
Parallel poll configure.
ibrd count
Read data where
count
is the bytes to read.
ibrda count
Read data asynchronously where
count
is the bytes to read.
ibrdf flname
Read data to file where
flname
is pathname of file to read.
ibrpp
Conduct a parallel poll.
ibrsp
Return serial poll byte.
ibsad v
Change secondary address.
ibstop
Abort asynchronous operation.
ibtmo v
Change/disable time limit.
ibtrg
Trigger selected device.