Erst (27), Epwr (28), Solutions – National Instruments NI-488.2 User Manual
Page 115

Appendix C
Error Codes and Solutions
© National Instruments Corporation
C-11
ERST (27)
ERST results when an event notification was cancelled due to a reset of the
interface.
An
ibwait
call pending in the driver returns ERST in the following
situations:
•
Another thread in the same process calls
ibonl
using the same unit
descriptor as ibwait.
•
Another thread or another process issues a board-level
ibonl 1
.
An
ibnotify
Callback may be invoked with ERST in the following
situations:
•
Another process issues a board-level
ibonl 1
.
Solutions
Do not call
ibonl
with
ibwait
calls still pending in the driver.
Prevent other applications from calling
ibonl
by locking the interface
with
iblck
.
EPWR (28)
EPWR results when an interface loses power. This often results when the
system goes to and returns from a standby state.
Solutions
Take all handles offline and reinitialize the application.
Quit the application and restart.
Disable standby and hibernate modes on the PC.