Moisture collector cap replacement

23

Replacing the moisture cap

Moisture cap should be replaced in a clean dry place. New Moisture cap can be exposed for no

more than 1-2 minutes.

The following is required for replacement of cartridge:

• Prepare spare cartridge supplied with your unit;

• With supplied key unscrew the moisture collector

cartridge that is full of moisture from the NVD and immediately
replace it with a new cartridge;

• Screw in the replacement cartridge until rubber O-ring is

visibly deformed.

NEWCON OPTIK

warrants this product against defects in material and workmanship for

one year from the date of the original date of consumer’s purchase, but no more than 18 months
from the date of manufacturing. Longer warranty periods are available, subject to the terms of
specific sales contract. Should your Newcon product prove defective during this period, please
bring the product securely packaged in its original container or an equivalent, along with proof
of the date of original purchase, to your Newcon Dealer. Newcon will repair (or at its option
replace with the same or comparable model), the product or part thereof, which, on inspection

by Newcon, is found to be defective in materials or workmanship.

What This Warranty Does Not Cover:

NEWCON

is not responsible for warranty service should the product fail to be properly

maintained or fail to function properly as a result of misuse, abuse, improper installation, neglect,
damage caused by disasters such as fire, flood, lightning, improper electrical current, or service
other than by a NEWCON Authorized Service. Postage, insurance, or shipping costs incurred in
presenting your NEWCON product for warranty service are your responsibility. Please include a
cheque or money order made out to NEWCON OPTIK for the amount of $15.00 to cover shipping

and handling within North America

WARRANTY

22

• In order to restore moisture filled cartridge it is required to unscrew the cap of Moisture collector

cartridge with the key provided, empty the silica gel into clean metallic container and place the
container in the heat source (i.e. electric stove, camping stove etc.)

Silica gel can never be directly exposed to fire. To restore silica gel the temperature should be

between 150 to 170°Ñ. Silica gel will dry with in 3 to 4 hours.