beautypg.com

Soldering, Definitions – Philips TDA2615 User Manual

Page 11

background image

1995 May 08

11

Philips Semiconductors

Product specification

2

×

6 W hi-fi audio power amplifier

TDA2615

SOLDERING

Plastic single in-line packages

B

Y DIP OR WAVE

The maximum permissible temperature of the solder is
260

°

C; this temperature must not be in contact with the

joint for more than 5 s. The total contact time of successive
solder waves must not exceed 5 s.

The device may be mounted up to the seating plane, but
the temperature of the plastic body must not exceed the
specified storage maximum. If the printed-circuit board has

been pre-heated, forced cooling may be necessary
immediately after soldering to keep the temperature within
the permissible limit.

R

EPAIRING SOLDERED JOINTS

Apply the soldering iron below the seating plane (or not
more than 2 mm above it). If its temperature is below
300

°

C, it must not be in contact for more than 10 s; if

between 300 and 400

°

C, for not more than 5 s.

DEFINITIONS

LIFE SUPPORT APPLICATIONS

These products are not designed for use in life support appliances, devices, or systems where malfunction of these
products can reasonably be expected to result in personal injury. Philips customers using or selling these products for
use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such
improper use or sale.

Data sheet status

Objective specification

This data sheet contains target or goal specifications for product development.

Preliminary specification

This data sheet contains preliminary data; supplementary data may be published later.

Product specification

This data sheet contains final product specifications.

Limiting values

Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or
more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation
of the device at these or at any other conditions above those given in the Characteristics sections of the specification
is not implied. Exposure to limiting values for extended periods may affect device reliability.

Application information

Where application information is given, it is advisory and does not form part of the specification.