beautypg.com

Standard installation – Pentair GreatWhite Automatic Pool Cleaner User Manual

Page 12

background image

6

Great White Installation and User’s Guide

Standard Installation

(Continued)

The vacuum regulator must be installed in conjunction with the reducer cone (Figure 10). The reducer cone
is required to make most skimmer connections. It will keep the hose and vacuum regulator in place once
the filter system is stopped.

To install the vacuum regulator, insert the vacuum regulator and reducer cone in the skimmer. Attach the
end of the hose to the regulator (Figure 11).

Make sure the vacuum regulator is submerged at all times. If not, the pump will suck air through the
vacuum regulator and lose prime. This could damage the pump.

Figure 10

Figure 11: Vacuum regulator installed in the skimmer with the hose attached

Skimmer

Vacuum

Regulator

To Pump

Reducer Cone