Hour meter – Precor p20 User Manual
Page 22
20
Operating and Maintaining the P20 Console
Event
Number
Description of Event
22
No motor pulses at start up
23
Motor pulses missing after start up
24
Reduce speed requested, speed is not reducing
26
Motor pulse width incorrect
27
Too much drive motor current
28
Temperature too high
29
Excessive AC input current
30
Communications event lower board to upper board
31
Incorrect Communications event upper board to
lower board
32
Communication event upper board to lower board
33
Incorrect communications event lower board to
upper board
40
Lift motion detected
42
Lift position value out of range
43
Zero switch not found
44
Un-commanded lift motion
45
Lift going in the wrong direction
50
Too much brake (magnet) current
53
Cannot read target, cannot find home switch
54
Target pulses lost during operation
55
Brake home switch activated unexpectedly
60
Auto Stop sensor failure (treadmill)
61
Auto Stop not present (treadmill)
Hour Meter
Tracks the number of hours that a piece of equipment has
run. The equipment also tracks elapsed minutes, but the value
that displays is rounded up the nearest full hour.