beautypg.com

Pitco Frialator 26 User Manual

Page 26

background image

1-17

c. Let the fryer cycle 4 to 6 times to ensure that the temperature has stabilized. Compare the

thermometer temperature against the thermostat setting. If the values are more than 5°F
apart, go to step d. If the values are within 5°F, the thermostat is operating correctly.

d. Loosen the set screw that holds the thermostat knob to its shaft.

e. Rotate the thermostat dial, without moving the shaft, to the temperature indicated on the

thermometer. Tighten the set screw on the thermostat dial to lock the dial in place.

f. Adjust the thermostat to a new setting and allow the fryer to cycle 4 to 6 times at the new

setting. Check the thermometer temperature against the dial setting. If the temperature
is ±5°F of the thermostat dial setting, remove the thermometer and replace the tube screen.
If the temperature is greater than ±5°F away from the dial setting, perform the above
procedure again.

This manual is related to the following products: