Setting the timer, Convenience operation – Panasonic CS-C9CKP User Manual

Page 3

background image

MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.

MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.

Heat Pump Model

MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.

Swing up/down
Automatically

Move up/down
Automatically

MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.

– When the discharge air

temperature is low such
as at the start of heating
operation, the air blows
at horizontal level. As
the temperature rises,
the hot air blows at a
downward direction.

– To stop this operation,

press MANUAL.

HEAT Operation

AUTO

COOL / DRY Operation

AUTO

Swing up/down
Automatically

Operation Details

COOL – Cooling Operation

To set the room temperature at your preference
cooling comfort.

AUTO – Automatic Operation

Sense indoor temperature to select the optimum
mode.

Temperature is not displayed on the remote control
during AUTO operation.

DRY – Soft Dry Operation

A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.

During Soft Dry operation, the indoor fan operates at
Low fan speed.

HEAT – Heating Operation
(for Heat Pump Model only)

Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.

Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.

FAN – Air Circulation Operation
(for Cooling Model only)

When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
2°C below the set temperature.
(It is useful when using a heater).

Setting the Fan Speed

• Press

4 to select:-

FAN

– Low Fan Speed

FAN

– Medium Fan Speed

FAN

– High Fan Speed

AUTO
FAN

Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.

Setting the Vertical Airflow Direction

• Press

5 or 6 to select:-

Cooling Model

Setting the Horizontal Airflow Direction

Use this air conditioner under the following

conditions:

Cooling Model

• Adjust it manually

Notes

If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.

If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

Heat Pump Model

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature

Minimum Temperature

WBT

23

11

DBT

43

16

WBT

26

11

Indoor

Outdoor

Unit in °C

DBT

32

16

DBT: Dry Bulb Temp
WBT: Wet Bulb Temp

Maximum Temperature-Cooling
(Maximum Temperature-Heating)

Minimum Temperature-Cooling
(Minimum Temperature-Heating)

DBT

32

(30)

16

(16)

WBT

23

(-)

11

(-)

DBT

43

(24)

16

(-5)

WBT

26

(18)

11

(-6)

Indoor

Outdoor

Unit in °C

36°

36°

61°

COOL / DRY Operation

AUTO

FAN Operation

AUTO

SETTING THE TIMER

Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.

ON-TIMER Operation

To start the air conditioner operation automatically.
• Press

1 to set the operation.

• Press

2 to increase or decrease the time.

• Then press

3.

• To cancel this operation, press

4.

OFF-TIMER Operation

To stop the air conditioner operation automatically.
• Press

5 to set the operation.

• Press

2 to increase or decrease the time.

• Then press

3.

• To cancel this operation, press

4.

Timer Mode Operation Details

• When the ON-Timer is set, operation will start

before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.

• Once the ON/OFF Timer is set, operation will start/

stop at the set time everyday.

• The current time is not displayed when the timers

are set.

• When both timers are used together, the TIMER

mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.

CONVENIENCE OPERATION

Powerful Mode Operation

To obtain the set temperature quickly.
• Press

6.

* Powerful mode indicator (orange) on the indoor

unit will light up.

* Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.

Powerful Mode Operation Details

• The changes of the temperature and airflow volume

are automatic.

• The remote control display remains unchanged.
• If operation mode button is pressed, powerful

operation will be cancelled.

• During FAN – Air circulation operation, the powerful

operation are not available.
(cooling model only)

Quiet Mode Operation

To provide quiet operation.
• Press

7.

* Quiet mode indicator on the indoor unit will light

up.

• To cancel this operation, press once more.

Operation Details

• Air flow sound will reduce during operation.

Ionizer Mode Operation

Produce negative ion for fresh air.
• Press

8.

* Ion mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.

Operation Details

• Air conditioner ON:

Provide negative ion during operation.

• Air conditioner OFF:

Provide negative ion with FAN operation.

• If blinking, press

8 twice.

If still blinking, please call service.

CHECK

AUTO

AUTO HEAT

DRY FAN

COOL

FAN

AUTO

RESET CLOCK

MODE

POWERFUL

QUIET

FAN SPEED

AIR SWING

OFF

CANCEL

ON

SET

1

2

3

TIMER

OFF/ON

AUTO

MANUAL

3

6

4

1

7

5

2

8

Airflow

volume

Super High

Automatic

Powerful Mode

Operation

COOL / DRY

HEAT

(for Heat Pump

model only)

Temperature

3°C lower

than set temp.

3°C higher

than set temp.

Heat Pump Model

COOL,DRY, –>15 minutes

in advance

HEAT, AUTO –>30 minutes

in advance

Cooling Model

COOL,DRY, –> 15 minutes
AUTO

in advance

34

CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6