14 troubleshooting, General, No connectivity – Perle Systems C-100-XXXXX User Manual

Page 14: Method 1

background image

Fast Ethernet Media Converter – Installation Guide

14

Troubleshooting

General

Ensure the module is correctly seated to the backplane in the

MCR Chassis. The PWR LED should be on solid.

Ensure both devices on either end of the fiber are

compatible. If using a simplex fiber connection, ensure that
you have both an Upstream (U) and Downstream (D) Media
Converter.

Ensure all cabling is of the correct type and is in good

working order.

For duplex fiber connections, ensure the RX and TX has

been reversed between the two Media Converters.

No connectivity

If unable to get full connectivity with all DIP switches in the UP
position, these methods are recommended for troubleshooting.

Method 1

1. If the Module is a CM-100, set the Auto-Config jumper (J6)

to SW so that switches are being read.

2. Set the Link mode to Standard (SW2 – Down) on both

Media Converters. Leave all other switches in the Up
position.

3. Connect the near end device to the copper connection. The

LKC LED indicates good copper connection. If the LKC LED
is not lit, then check the copper cable and the attached
device. Repeat for the far end Media Converter.

4. Connect the fiber cable to both converters. The LKF LED

indicates good fiber connection. If no LKF LED then check
the fiber cabling.

5. Return Media Converter to the desired configuration.