beautypg.com

Characteristics, Catv amplifier module bgy88 – Philips BGY88 User Manual

Page 3

background image

1997 Apr 09

3

Philips Semiconductors

Product specification

CATV amplifier module

BGY88

CHARACTERISTICS

Table 1

Bandwidth 40 to 450 MHz; T

mb

= 35

°

C; Z

S

= Z

L

= 75

Notes

1. f

p

= 55.25 MHz; V

p

= 46 dBmV;

f

q

= 343.25 MHz; V

q

= 46 dBmV;

measured at f

p

+ f

q

= 398.5 MHz.

2. Measured according to DIN45004B;

f

p

= 440.25 MHz; V

p

= V

o

= 62 dBmV;

f

q

= 447.25 MHz; V

q

= V

o

6 dB;

f

r

= 449.25 MHz; V

r

= V

o

6 dB;

measured at f

p

+ f

q

f

r

= 438.25 MHz.

3. The module normally operates at V

B

= +24 V, but is able to withstand supply transients up to +30 V.

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

G

p

power gain

f = 50 MHz

33.5

35.5

dB

f = 450 MHz

35

37

dB

SL

slope cable equivalent

f = 40 to 450 MHz

0.5

2.5

dB

FL

flatness of frequency response

f = 40 to 450 MHz

±

0.3

dB

S

11

input return losses

f = 40 to 80 MHz

20

dB

f = 80 to 160 MHz

19

dB

f = 160 to 450 MHz

18

dB

S

22

output return losses

f = 40 to 80 MHz

20

dB

f = 80 to 160 MHz

19

dB

f = 160 to 450 MHz

18

dB

CTB

composite triple beat

60 channels flat; V

o

= 46 dBmV;

measured at 445.25 MHz

58

dB

X

mod

cross modulation

60 channels flat; V

o

= 46 dBmV;

measured at 55.25 MHz

59

dB

d

2

second order distortion

note 1

70

dB

V

o

output voltage

d

im

=

60 dB note 2

62

dBmV

F

noise figure

f = 450 MHz

6

dB

I

tot

total current consumption

DC value; V

B

= +24 V; note 3

320

340

mA