q Auto Iris Lens Connector
This connector is used to connect the auto iris lens
with a 4-pin male connector supplied as a standard
accessory (Part No. YFE4191J100).
w Flange-back Adjusting Ring (FB)
This ring is used to adjust the back focal length or
picture focus. Rotate this ring upward or downward
for a CS-mount lens. In case of using a C-mount
lens, adjust it with the C-mount adapter.
e Lens (Option)
r Focus Fixing Screw (LOCK)
t Camera Mounting Screw Hole
This hole is used to mount the camera onto a
mounting bracket.
y Down Button (
K)
This button is used to move the cursor downward. It
is also used to select items in the CAM SET UP
menu.
u Right Button (
M)
This button is used to move the cursor to the right.
It is also used to select the mode and can be used
to adjust some levels.
i Left Button (
L)
This button is used to move the cursor to the left. It
is also used to select the mode and can be used to
adjust some levels.
o Up Button (
J)
This button is used to move the cursor upward. It is
also used to select items in the CAM SET UP menu.
!0 Set Button (
I)
This button is used to activate an item selected in
the CAM SET UP menu.
!1 Gen-lock Termination Switch (Hi-Z, G/L 75
Ω)
Set this switch to Hi-Z when a gen-lock video input
signal is looped through. In all other cases, set this
switch to 75
Ω.
!2 RS-485 Termination Switch (Hi-Z, RS485 LINE
TERM)
This switch is used to terminate of the RS485 termi-
nal. Normally keep it LINE TERM position.
!3 Full duplex/Half duplex Selection Switches
(4-LINE/2-LINE)
These triple switches are used to select either full
duplex (left side) or half duplex (right side) for the
communication lines.