beautypg.com

Tungsten halogen par lamps, Electrical,technical and ordering data – Philips PAR-56 User Manual

Page 2

background image

Type

Diameter

M.O.L.

(In.)

(In.)

500PAR56Q/NSP

7

5

500PAR56Q/MFL

7

5

500PAR56Q/WFL

7

5

1000PAR64Q/NSP

8

6

1000PAR64Q/MFL

8

6

1000PAR64Q/WFL

8

6

FFN

8

6

FFP

8

6

FFR

8

6

FFS

8

6

Diameter

M.O

.L.

Rated

Std.

Heat

Average Approx.

Product ANSI

Pkg.

Resistant

Bulb

Beam

Candle-

Initial

Life

Color

Number

Description

Code

Watts

Qty. Volts

Description

Type

Base

Angle

1

Power

2

Lumens

(Hrs.)

3

Temp.

35619-6

500PAR56Q/NSP

500

8

120

Narrow Spot

PAR-56

Mog. End

17 x 34

88,000

3500

4000

3000

35621-2

500PAR56Q/MFL

500

8

120

Med. Flood

PAR-56

Mog. End

20 x 48

47,000

3800

4000

3000

35620-4

500PAR56Q/WFL

500

8

120

Wide Flood

PAR-56

Mog. End

28 x 70

22,500

5000

4000

3000

27555-2

1000PAR64Q/NSP

1000

8

120

Narrow Spot

PAR-64

Ext. Mog End

16 x 28

200,000

9800

4000

3000

27556-0

1000PAR64Q/MFL

1000

8

120

Med. Flood

PAR-64

Ext. Mog End

24 x 44

80,000

12,000

4000

3000

27558-6

1000PAR64Q/WFL

1000

8

120

Wide Flood

PAR-64

Ext. Mog End

42 x 76

31,000

14,800

4000

3000

34350-9

1000PAR64QVNSP

FFN

1000

8

120

Very Narrow Spot

PAR-64

Ext. Mog End

12 x 6

400,000

11,000

800

3200

34351-7

1000PAR64QNSP

FFP

1000

8

120

Narrow Spot

PAR-64

Ext. Mog End

14 x 7

330,000

12,000

800

3200

34352-5

1000PAR64QMFL

FFR

1000

8

120

Med. Flood

PAR-64

Ext. Mog End

28 x 12

120,000

14,000

800

3200

34353-3

100PAR64QWFL

FFS

1000

8

120

Wide Flood

PAR-64

Ext. Mog. End

55 x 22

40,000

19,000

800

3200

Tungsten Halogen PAR Lamps

Electrical,Technical and Ordering Data

(Subject to change without notice)

Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation

Printed in USA 07/05

P-1223-D

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050

A Division of Philips Electronics Ltd.

www.philips.com

1) Beam Spread to 50% peak candlepower.
2) Candlepower Average in central 5˚ cone for spot to 10˚ cone for flood.
3) Rated Average Life is the length of operation (in hours) at which point an average of 50% of the lamps will still be operational and 50% will not.
Note: Lamps can be operated in ANY position.

Operation & Handling

Studio and theater lamps require care to gain
optimum performance with every use. Handling
the glass of a quartz lamp should be avoided. It is
advisable to use gloves when touching a lamp.
Should the lamp be touched, careful cleaning can
be done with a solvent such as alcohol. Shielding
of halogen lamps is generally considered an
advisable precaution.

Average Performance Characteristics

Fig. 1 and Fig. 2 — Data becomes more
inaccurate beyond 80–120%. Overvolting Stage
and Studio lamps can result in immediate failure;
undervolting increases live expectancy while
reducing color temperature.

Fig. 1 Variation of life characteristics

with applied voltage

300

260

220

180

140

100

60

20

88

92

96

100

104

108

Percentage Life

Percentage Rated Volts

Fig. 2 Variation of light characteristics

with applied voltage

140

100

60

20

88

92

96

100

104

108

Percentage Life

Percentage Rated Volts

Lumens

Watts

This manual is related to the following products: