Pdp-614mx external control manual – Pioneer PDP-614MX External Control Manual RS-232C User Manual
Page 32
PDP-614MX External Control Manual
32
42. FREQUENCY Request(SIGNAL INFORMATION)
Function
The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync
polarity, Mode, and Resolution of the plasma monitor.
Transmission Data
1FH 80H 60H 26H 00H CKS
ACK
7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS
Horizontal frequency
DATA00: Integer part
00H: 0 (No signal: 00H)
:
FFH : 255
DATA01: One decimal place 00H: 0 (No signal: 00H)
:
09H : 9
Vertical frequency
DATA02: Integer part
00H: 0 (No signal: 00H)
:
FFH : 255
DATA03: One decimal place 00H: 0 (No signal: 00H)
:
09H : 9
Horizontal sync polarity
DATA04
00H : -
01H : Positive
02H : Negative
Vertical sync polarity
DATA05
00H : -
01H : Positive
02H : Negative