beautypg.com

Pdp-614mx external control manual application, Connections – Pioneer PDP-614MX External Control Manual RS-232C User Manual

Page 2

background image

PDP-614MX External Control Manual

Application

These specifications are applicable to plasma monitors and communications control from external equipment.

Connections

Connections should be made as described below.

plasma monitor

External equipment

e.g., Personal computer












1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.

Type of connector: D-Sub 9-pin male

No. Pin Name
1 No

Connection

2 RXD

(Receive

data)

3

TXD (Transmit data)

4

DTR (DTE side ready)

5 GND
6

DSR (DCE side ready)

7

RTS (Ready to send)

8

CTS (Clear to send)

9 No

Connection

2

This manual is related to the following products: