Paxar Monarch RF Link 7400 User Manual
Page 11
6 RF link Operating Instructions
RF link Operating Instructions 11
Printers
To install external RF link modules onto the printers:
1. Insert a 9-volt (PP3) battery in the module. See “Inserting Batteries” for
more information.
2. Attach VELCRO
to the serial port sides of the printer and the external
module. Place the VELCRO so the cable on the module can reach the
serial port.
3. Using the VELCRO, attach the module to the printer. Note that on the
Renegade 4 printer, you must place the module so the cable faces
down. On the Rascal printer, place the module so the cable faces up.
9490 Printer
9450 Printer
4. Insert the cable from the module into the printer’s serial port.
Rascal Printers
To link a Rascal printer to a data collection terminal:
1. Turn the printer, terminal, and the RF link modules off.
2. Turn on the printer.
3. Turn on the printer's RF link module. The green LED turns on.
4. Turn on the terminal's RF link module. The green LED turns on. Then
the LEDs on both modules start blinking.
5. Turn on the terminal.
O p e r a t i n g R F l i n k
To operate RF link:
1. Initialize the printer/terminal connection (see "Linking RF link" for more
information).
2. Use the printer and the terminal as you normally would.
NOTE: You can walk out of the 3-meter range and scan up to 4 items.
When you walk back into the 3-meter range, the printer prints those
labels.
There are no software configurations or commands to change the operating
parameters.