4.2 WIRING FOR MULTIPOINT CIRCUITS

The Model 1070 supports multi-point applications using either a

star or daisy chain topology. Both topologies require special wiring, as
well as specific DIP switch settings for master and slave units.

4.2.1 DAISY CHAIN TOPOLOGY

Using a daisy chain topology, you may connect several Model

1070s together in a master/slave arrangement. Maximum distance
between the units will vary based upon the number of drops, data rate,
wire gauge, etc. Call Patton Technical Support for specific distance
estimates.

Figure 4 (below) shows how to wire the two-pair cables properly for

a Model 1070 daisy chain topology. Note that the ground connection is
not needed.

In a multipoint topology, you must configure the CARRIER

ENABLE switch (DIP switch 8) differently for the master Model 1070
than for the slave Model 1070(s). Here are the proper DIP switch
settings for a daisy chain topology:

Switch Number

8

Master Positions

OFF

Slave Positions

ON

9

HOST

FIRST SLAVE

OTHER SLAVE(S)

XMT

RCV

RCV

XMT

RCV

RCV

RCV

XMT

XMT

RCV

XMT

XMT

Figure 4. Model 1070 daisy chain wiring

4.2.2 STAR TOPOLOGY

In a star topology, you may connect several Model 1070s together

in a master/slave arrangement. Maximum distance between the units
will vary based upon the number of drops, data rate, wire gauge, etc.
Call Patton Technical Support for specific distance estimates.

Figure 5 (below) shows how to wire the two-pair cables properly for

a Model 1070 star topology. Note that the ground connection is not
needed.

In a multipoint topology, you must configure the CARRIER

ENABLE switch (DIP switch 8) differently for the master Model 1070
than for the slave Model 1070(s). Here are the proper DIP switch
settings for a star topology:

Switch Number

8

Master Positions

OFF

Slave Positions

ON

4.2 RS-232 CONNECTION

To connect the Model 1070 to data terminal hardware (PC, host,

terminal, etc.), use a

straight through RS-232 cable. To connect the

Model 1070 to data communications hardware (modem, multiplexer,
etc.), use a

null modem RS-232 cable.

HOST

FIRST SLAVE

SECOND SLAVE

XMT

RCV

RCV

XMT

RCV

RCV

RCV

XMT

XMT

RCV

XMT

XMT

Figure 5. Model 1070 star wiring