13

Chapter 4. Configuration

After installing the ParaStation software successfully, only few modifications to the configuration file
parastation.conf(5) have to be made in order to enable ParaStation on the local cluster.

4.1. Configuration of the ParaStation system

Within this section the basic configuration procedure to enable ParaStation will be described. It covers the
configuration of ParaStation5 using TCP/IP (Ethernet) and the optimized ParaStation5 protocol p4sock.

The primarily configuration work is reduced to editing the central configuration file

parastation.conf

,

which is located in

/etc

.

A template file can be found in

/opt/parastation/config/parastation.conf.tmpl

. Copy this file

to

/etc/parastation.conf

and edit it as appropriate.

This section describes all parameters of

/etc/parastation.conf

necessary to customize ParaStation

for a basic cluster environment. A detailed description of all possible configuration parameters in the
configuration file can be found within the parastation.conf(5) manual page.

The following steps have to be executed on the frontend node to configure the ParaStation daemon psid(8):

1. Copy template

Copy

the

file

/opt/parastation/config/parastation.conf.tmpl

to

/etc/

parastation.conf

.

The template file contains all possible parameters known by the ParaStation daemon psid(8). Most
of these parameters are set to their default value within lines marked as comments. Only those that
have to be modified in order to adapt ParaStation to the local environment are enabled. Additionally all
parameters are exemplified using comments. A more detailed description of all the parameters can be
found in the parastation.conf(5) manual page.

The template file is a good starting point to create a working configuration of ParaStation for your
cluster. Beside basic information about the cluster, this template file defines all hardware components
ParaStation is able to handle. Since these definitions require a deeper knowledge of ParaStation, it is
easier to copy the template file anyway.

2. Define Number of nodes

The parameter NrOfNodes has to be set to the actual number of nodes within the cluster. Front end
nodes have to be considered as part of the cluster. E.g. if the cluster contains 8 nodes with a fast
interconnect plus a front end node then NrOfNodes has to be set to 9 in order to allow the start of parallel
tasks from this machine.

3. HWType

In order to tell ParaStation which general kind of communication hardware should be used, the HWType
parameter has to be set. This could be changed on a per node basis within the nodes section (see below).

For clusters running ParaStation5 utilizing the optimized ParaStation communication stack on Ethernet
hardware of any flavor this parameter has to be set to:

HWType { p4sock ethernet }

This will use the optimized ParaStation protocol, if available. Otherwise, TCP/IP will be used.