Appendix a model 2707, g.703 specifications, Network data rate, 048 mbps – Patton electronic X.21 Interfaces User Manual
Page 16: Network connector, Rj-48c/dual coax bnc (2707/d), Nominal impedance, 75/120 ohm, Line coding, Selectable ami or hdb3, Line framing

15
APPENDIX A
MODEL 2707, G.703 SPECIFICATIONS
Network Data Rate:
2.048 Mbps
Network Connector:
RJ-48C/Dual Coax BNC (2707/D)
Nominal Impedance:
75/120 Ohm
Line Coding:
Selectable AMI or HDB3
Line Framing:
G.703 (Unframed)
Clocking:
Internal or Network (Receive Recover)
Distance:
Maximum 1.8 km (6,000 ft.) on 24 AWG
Cable
Configuration:
One 8-Position DIP Switches
Power Supply:
+5VDC External power supply/100-240VAC,
50-60Hz, 0.4A; or 48VDC Power Supply
Humidity:
Up to 90% non-condensing
Temperature:
0 to 50˚ C
Dimensions:
9.0 x 5.3 x 2.0 cm (3.5”L x 2.1”W x 0.78”H)